欢迎来到上海宸乔生物科技有限公司网站!
咨询热线

18801803238

当前位置:首页   >  产品中心  >  层析柱  >  离子交换层析空柱  >  PZ10-10AA层析柱内径5mm 10mm 耐压50bar 耐有机

层析柱内径5mm 10mm 耐压50bar 耐有机

简要描述:层析柱内径5mm 10mm 耐压50bar 耐有机
PZ Columns适用于水溶液体系并与常用的液相色谱 应用溶剂兼容’如蛋白质纯化的溶剂。
低压力或重力自流输送的经济型模块化柱’能使洗 脱液在柱床上均匀分布。
层析柱可以实现轴向压缩技术(一端可调轴向压缩 和两端可调轴向压缩)。
有9种直径和各种长度。

  • 产品型号:PZ10-10AA
  • 厂商性质:生产厂家
  • 更新时间:2025-10-22
  • 访  问  量:8135

详细介绍

层析柱内径5mm 10mm 耐压50bar 耐有机

Chromatography Column, ID 5mm / 10mm , Max Pressure 50 bar, Resistant to Organic Solvent 

清洗

建议:第一次使用时请先清洗玻璃柱管和连接处,以便去除在生产过程中可能残留的物质。可选用常规的洗涤剂或实验室级去污剂来清洗,我们的玻璃柱管亦可高温消毒。


Cleaning

Recommendation: Before initial use, please clean the glass column tube and connections to remove any potential residues from the manufacturing process. Conventional detergents or laboratory-grade cleaning agents can be used for cleaning. Our glass column tubes can also be sterilized at high temperatures.


安装固定端
1、首先要确保玻璃管和固定帽上的螺纹没有碎片和毛刺以防止安装时螺纹被损坏。
2、用流动相或适用的溶剂充分润湿O型-密封圈。

3、轻轻将柱床支撑的固定末端缓慢地垂直推进柱管,并保持整个过程在一条直线完成,一定要避免安装时有斜角以免损坏密封圈和玻璃管末端。


Installing the Fixed End

1.First, ensure the threads on the glass tube and the fixed end cap are free of debris and burrs to prevent damage during installation.

2.Thoroughly wet the O-ring seal with the mobile phase or a suitable solvent.

3.Gently and slowly insert the fixed end with the column bed support vertically into the column tube, maintaining alignment throughout the process. Avoid any angled insertion to prevent damage to the seal and the end of the glass tube.


填充层析柱
完成以上工序后,现在可以装填层析填料。由于市面上的填料种类众多,各品种要求不一,我们推荐您在装柱时最好按照填料制造商的指导来装填层析柱。
我们已经预先在柱管上印制了柱床的横截面积和柱高刻度,以方便您装填时计算柱床体积和高度。每个刻度间距是10毫米,我们同时也印制了柱管耐受压力。我们提供的刻度仅作为参考。


Column Packing

After completing the steps above, the column can now be packed with chromatography media. As there are numerous types of media available, each with potentially different requirements, we recommend packing the column according to the media manufacturer's instructions.
We have pre-printed the column bed's cross-sectional area and height markings on the column tube to facilitate the calculation of bed volume and height during packing. The scale intervals are 10 mm. We have also printed the pressure resistance of the column tube. The scales we provide are for reference only.


安装适配器
1、首先确保玻璃管和固定帽没有破损。
2、关闭层析柱出口防止柱床干涸。
3、调整柱管中液面至少比柱床高出1-2cm。
4、将适配器上的调节帽和固定帽一起旋到靠近筛板处。
5、 用水充分润湿O型-密封圈和筛板,并确保筛板中没有气泡残留。
6、 轻轻将适配器垂直推入玻璃管,直到固定帽可以拧到玻璃柱管上,请确保整个操作在一条直线上完成。
7、 将固定帽拧紧后再往回拧15°即可,注意请不要将固定帽拧过紧。
8、 握住固定帽,同时缓慢逆时针旋转调节帽将适配器上的柱塞调到柱管中需要的位置。

注:通常在使用时柱床高度会略有下降,我们建议装柱时可将适配器的柱塞调节到略低于柱床沉降后的高度。


Adapter installation

1.First, ensure the glass tube and the fixed end cap are undamaged.

2.Close the column outlet to prevent the column bed from drying out.

3.Adjust the liquid level in the column tube to be at least 1-2 cm above the top of the column bed.

4.Screw the adjustment nut and the fixed cap on the adapter together down close to the frit.

5.Thoroughly wet the O-ring seal and the frit with water, ensuring no air bubbles are trapped in the frit.

6.Gently push the adapter vertically into the glass tube until the fixed cap can be screwed onto the glass column tube. 7.Ensure the entire operation is performed in a straight line.

8.After tightening the fixed cap, unscrew it by approximately 15°. Please avoid over-tightening the fixed cap.

Hold the fixed cap and slowly turn the adjustment nut counterclockwise to lower the adapter plunger to the required position within the column tube.
Note: The bed height often decreases slightly during use. We recommend adjusting the adapter plunger to a position slightly below the settled bed height after packing.



连通层析柱

我们提供的管线上的1/4"-28接头是专用于连接柱管连接帽的。管线的另一端可自行添加与您层析系统所匹配的接头。


Column Connecting

The 1/4''-28 fittings on the tubing we supply are specifically designed for connecting to the column tube end cap. You can add a fitting compatible with your chromatography system to the other end of the tubing.


保存层析柱
如要保存空柱,只需用清水冲洗干净即可,如装有填料,亦可保存在20%乙醇中。

请避免O型-密封圈上残留有如IPA这类的有机溶剂,否则其会溶解密封圈,并使其粘连在柱管内壁。


Column Storage

If storing an empty column, simply rinse it thoroughly with clean water. If packed with media, it can also be stored in 20% ethanol.
Avoid leaving organic solvents (such as IPA) on the O-ring seals, as they can dissolve the seals and cause them to stick to the inner wall of the column tube.


注意事项
1、 玻璃管螺纹处相对易被损坏,装柱时请尽量不要有斜角,并轻轻进行。
2、 O型-密封圈在装柱时,请充分润湿,否则会增加其与柱管间摩擦力,造成轴向压缩困难,更可能导致密封圈损坏。
3、 如需更换筛板,推荐使用我们专门用于筛板拆卸的工具,以免损坏适配器末端。

4、 有时填料或使用的溶剂可能会残留在 O型密封圈上,导致适配器移动困难,此时可以将层析柱放入冰箱冷藏室数个小时,这样有助于移动适配器。


Precautions

1.The threaded parts of the glass tube are relatively fragile. During installation, try to avoid angled forces and handle gently.

2.When installing the adapter, ensure the O-ring is thoroughly wetted. Otherwise, friction between the seal and the column tube may increase, making axial compression difficult and potentially damaging the seal.

3.If replacing the frit, we recommend using our specialized tool for frit removal to avoid damaging the adapter end.

4.Sometimes media particles or used solvents may remain on the O-ring, making the adapter difficult to move. Placing the column in a refrigerator for several hours may facilitate adapter movement.


层析柱内径5mm 10mm 耐压50bar 耐有机

层析柱内径5mm 10mm 耐压50bar 耐有机


 

产品咨询

留言框

  • 产品:

  • 您的单位:

  • 您的姓名:

  • 联系电话:

  • 常用邮箱:

  • 省份:

  • 详细地址:

  • 补充说明:

  • 验证码:

    请输入计算结果(填写阿拉伯数字),如:三加四=7

联系我们

上海宸乔生物科技有限公司 公司地址:上海市阿克苏路1187号516室   技术支持:化工仪器网
  • 联系人:王经理
  • QQ:3004300903
  • 公司传真:021-59100893-802
  • 邮箱:sales@keyanwang.com.cn

扫一扫 更多精彩

微信公众号

网站二维码